A stylish woman sitting in a vintage lounge area with subtle lighting and wooden decor.

Fireplace Inspection in Compton

Ask About Fireplace Inspection

Flue Filmed Joint by Joint
Liner Sized to the Appliance
Written Price Per Item
Footage Handed Over
Based in Compton
Flue Filmed Joint by Joint
Liner Sized to the Appliance
Written Price Per Item
Footage Handed Over
Based in Compton

The Work, Item by Item

The smoke chamber sits above the damper, where the fireplace funnels into its flue, and few owners ever see it. We look up into it with a light and camera for rough or cracked parging, then check the damper, firebrick, lintel, hearth extension and the space to the mantel and trim. If a gas line feeds the fireplace, the valve and connector get a look too. Each part gets a photo and a short verdict.

Smoke chamber parging viewed by camera
Damper plate and frame tested for seal
Firebrick and its joints checked for gaps
Hearth extension depth measured
Mantel and trim clearance measured
Gas valve and connector seen where fitted

The Firebox, the Throat and the Bottom of the Flue

A fireplace inspection covers everything from the hearth floor up to where the flue tile starts. Inside the firebox we look at each firebrick and each joint. Cracks that run through a whole brick, joints where the refractory mortar has eroded deeper than a quarter inch, and a back wall that has started to bow are all reasons not to keep burning as is, because heat travels through those gaps into the brick behind and, in the worst cases, to framing. Above the firebox, the damper should swing open fully and close flat. Behind it, the smoke chamber narrows up into the flue, and in many older Compton fireplaces it is rough stepped brick that was never smoothed with mortar. That roughness slows the draft and collects creosote. We look at where the first tile sits on top of the chamber, because that joint carries the most heat in the whole chimney.

Outside the firebox, the hearth extension in front of the opening has to be solid masonry or tile on a noncombustible base and deep enough to catch a rolling log. Wood mantels and trim need clearance from the opening, which depends on how far they stick out. We measure both. Factory-built fireplaces, common in houses and condos built from the 1970s on, have their own rules: a metal firebox with refractory panels, a metal chimney pipe, and a listing plate that names the parts that go with it. We check the panels for cracks, the pipe sections we can see, and whether glass doors or a grate were added that the maker never approved. Many of those units in Compton condos and townhomes have never had their metal chimney looked at from the roof, and we check its cap and storm collar while we are up there. A missing or rusted piece up top often explains a rusty firebox below.

What It Costs and What You Do With the Findings

A fireplace inspection is part of a Level 1, which is $52, and it includes the visible flue from below and the top from the roof when it can be walked. You get a short written report with photos: what we saw, what each item means, and whether the fireplace is safe to use tonight. Common outcomes in Compton, Carson and Downey are simple. A firebox with a few eroded joints needs repointing with refractory mortar. A damper with a rusted plate gets repaired or replaced with a top-sealing damper. A factory-built unit with a cracked panel needs the matching part from its maker. Each of those comes with its own written price after the inspection. A cracked hearth extension may need to be rebuilt or extended, and that is priced the same way, in writing and on its own line, so it can be weighed against everything else on the report.

If the bottom of the flue shows cracking, or the chimney has a history you do not know, we will suggest moving up to a Level 2 at $370 so the camera can follow the whole flue. We explain why before anything is booked. If you are planning to change the fireplace, say with an insert or gas logs, tell us at the start, because the inspection then needs to answer whether the existing flue can carry the new appliance. Changing fuel or adding an appliance is one of the situations where the fire code expects the deeper look, because the old flue was sized and built for something else. The camera run tells us whether the existing tile can stay, needs a repair, or needs a stainless liner, and that answer shapes the whole project. We would rather you know it before you buy an insert. Book through the form and mention the age of the house and whether the fireplace is brick or a metal unit.

How Pemberton Chimney Contractors Works

Camera Before Price

The inside of the flue is seen before any figure is written

Sized Liners

Liner diameter worked out from the appliance outlet

Itemized Scope

Each repair on its own line with its own price

Footage Handed Over

Recordings and stills stay with you after the visit

Related Work

Chimney Sweep

A clean flue is a readable flue: brushes strip the deposits, then the camera checks each tile joint on the bare walls.

Details

Chimney Inspection

Flue tiles, liner joints and clearances read by eye and by camera, at whichever NFPA 211 level the chimney calls for.

Details

Chimney Repair

Repairs scoped from what the flue and brick show, ordered so the work that keeps heat and water in check comes first.

Details

Fireplace Repair

Firebrick, joints, smoke chamber parging and damper parts restored so the fire and its exhaust stay where they belong.

Details

Chimney Level 2 Inspection

Every foot of the flue filmed and saved, with the hidden stretches of chimney in the attic and crawl space checked too.

Details

Chimney Cap Installation

Stainless caps matched to the flue tile size and set high enough that rain and animals stay out while draft keeps moving.

Details

Chimney Flashing Repair

The metal seal where roof meets chimney rebuilt in overlapping layers, so roof runoff cannot slip behind the brick.

Details

Chimney Masonry Repair

Joints repointed, flaking brick replaced and the top courses checked, so rain stops reaching the flue tile from outside.

Details

Chimney Rebuilds

A failed stack taken down and laid up again around a new flue liner, sized for whatever will burn below it next.

Details

Fireplace Cleaning

Firebox, glass, hearth and surround cleaned on the room side, plus a light shone past the damper into the smoke chamber.

Details

Gas Fireplace Cleaning

Burner, pilot, logs and glass serviced, and the vent pipe checked so the exhaust from a gas flame leaves the house cleanly.

Details

Gas Fireplace Repair

Pilot, ignition, valve and venting faults traced with a meter and a look up the vent, then only the failed part replaced.

Details

Fireplace Remodel

A new surround, mantel or fuel planned around the flue first, so the finished fireplace still vents well and clears its trim.

Details

Fireplace Inserts

An insert sealed into the firebox with its own stainless liner, sized to the unit's outlet and run to the top of the flue.

Details

Pellet Stove Repair

Feed, igniter, blowers and sensors tested, and the pressurized vent pipe checked joint by joint for leaks into the room.

Details

Wood Stove Repair

Door seals, baffle, firebrick and the stovepipe or liner renewed so the stove burns slowly and its exhaust stays sealed.

Details

Gas Logs

Log sets matched to the firebox floor and to the flue they vent through, with the gas line and valve fitted to code.

Details

Chimney Seismic Retrofit

Older brick stacks braced or reinforced at the roof, with the liner filmed first so the retrofit protects a working flue.

Details

Chimney Crown Repair

The concrete slab around the flue tile sealed or recast, so water stops running into the gap between tile and brick.

Details

Dryer Vent Cleaning

Lint cleared from the dryer duct all the way from the machine to the outside hood, with airflow measured before and after.

Details

Chimney Liner Installation

Stainless liners sized to the appliance and run in one piece from the firebox or insert up to the top of the flue.

Details

Chimney Leak Repair

Water traced from the stain indoors to where it enters, whether crown, flashing, brick or an open flue, then sealed there.

Details

Chimney Waterproofing

A breathable repellent applied to sound brick above the roof, so rain beads off without sealing moisture inside.

Details

Chimney Damper Repair

Throat dampers freed, refitted or replaced, or swapped for a sealing top damper mounted on the flue tile.

Details

Chimney Chase Cover

Rusted tops on framed chimneys replaced with stainless or aluminum covers made to measure around the metal flue.

Details
Call (323) 524-5347