The Work, Item by Item
Framed chimneys with a metal flue are topped by a sheet-metal panel called a chase cover. Painted steel versions rust, hold puddles and drip into the chase, staining siding and rotting the framing. We measure the chase, check the flue pipe and the framing for water damage, then fit a made-to-measure stainless or aluminum cover, cross-broken so water runs off, with a sealed opening for the flue. Covers are priced after the roof measure.
What a Failing Cover Does to the Flue and the Framing
Many houses and condos around Compton, Carson and Cerritos built from the 1970s on have factory-built fireplaces with a metal flue, enclosed above the roof in a wood-framed box finished in stucco or siding. Capping that box is a metal pan, cut to the chase and pierced where the pipe rises through, with a ring sealing the opening. Nothing else stands between the rain and the framing below. Original covers were often thin galvanized steel, cut flat. Flat steel holds puddles, the puddles rust it, and rust spreads from the center until the cover leaks or rusts through. Then rain runs into the box, down the outside of the metal flue and onto the framing. The first sign is often rust streaks down the stucco below the top, a stain on the ceiling near the fireplace, or rust on the firebox top of the unit itself. On the camera, a metal flue under a leaking cover shows rust spots at the joints and at the bottom of the pipe.
We check the cover, the collar where the flue passes through, and the storm collar that sheds water off the pipe. Then we look inside the box, at the framing and the outside of the flue. If the stucco or siding has cracked near the top, we look at whether water has been getting in behind it as well. The metal flue is checked at the sections we can reach for rust, separated joints and missing screws, and where it is not visible we run the camera down from the top. Rot in the top plates of the framing is common under an old cover, and we probe it to see how far it goes. The firestop where the flue passes through the ceiling is checked too. Each finding gets a photo, so you know exactly what we saw before the quote arrives, and nothing is replaced until you have agreed to it in writing.
Replacement Covers and the Written Quote
A good replacement cover is stainless steel, made to the measured size of the chase, with the edges hemmed and a skirt that laps down over the outside of the box. The top is formed with a slope or cross break so water runs off rather than pooling, and the flue opening is raised with a collar so water cannot run into it. We measure each side of the box rather than trusting the old cover's size, because many chases are slightly out of square. On install we fasten the cover through the skirt, seal the storm collar on the flue pipe, and fit the flue cap back on top. If the framing inside is wet or rotted, or the metal flue has rusted, we stop and show you before the cover goes on.
Chase cover replacement is priced in writing after we measure, since the size of the chase, the number of flues and any repair to framing or flue set the job. The quote lists the cover, the collar, the cap and any framing or siding lines separately. If the metal flue itself has rusted badly, we explain the choices, including replacing the flue sections or the whole unit, each priced in writing. Covers are made to order once the measurements are set, so the quote also tells you what we will do to keep the chase dry until the new one is fitted, whether that is a temporary patch over the rust holes or a tarp tied down over the top. We also note the cap and spark screen on the flue pipe, which are often as rusted as the cover beneath them. Use the form to describe what you see on the outside of the chase.
How Pemberton Chimney Contractors Works
Camera Before Price
The inside of the flue is seen before any figure is written
Sized Liners
Liner diameter worked out from the appliance outlet
Itemized Scope
Each repair on its own line with its own price
Footage Handed Over
Recordings and stills stay with you after the visit
Where we offer chimney chase cover
Open a city for its housing, the flues common there, and how this job is planned on those streets.
No cities match that search. Try a nearby area name or neighborhood.
Related Work
Chimney Sweep
A clean flue is a readable flue: brushes strip the deposits, then the camera checks each tile joint on the bare walls.
DetailsChimney Inspection
Flue tiles, liner joints and clearances read by eye and by camera, at whichever NFPA 211 level the chimney calls for.
DetailsChimney Repair
Repairs scoped from what the flue and brick show, ordered so the work that keeps heat and water in check comes first.
DetailsFireplace Inspection
Room side checked from firebox to smoke chamber, the narrowing where a fireplace meets its flue and heat damage often hides.
DetailsFireplace Repair
Firebrick, joints, smoke chamber parging and damper parts restored so the fire and its exhaust stay where they belong.
DetailsChimney Level 2 Inspection
Every foot of the flue filmed and saved, with the hidden stretches of chimney in the attic and crawl space checked too.
DetailsChimney Cap Installation
Stainless caps matched to the flue tile size and set high enough that rain and animals stay out while draft keeps moving.
DetailsChimney Flashing Repair
The metal seal where roof meets chimney rebuilt in overlapping layers, so roof runoff cannot slip behind the brick.
DetailsChimney Masonry Repair
Joints repointed, flaking brick replaced and the top courses checked, so rain stops reaching the flue tile from outside.
DetailsChimney Rebuilds
A failed stack taken down and laid up again around a new flue liner, sized for whatever will burn below it next.
DetailsFireplace Cleaning
Firebox, glass, hearth and surround cleaned on the room side, plus a light shone past the damper into the smoke chamber.
DetailsGas Fireplace Cleaning
Burner, pilot, logs and glass serviced, and the vent pipe checked so the exhaust from a gas flame leaves the house cleanly.
DetailsGas Fireplace Repair
Pilot, ignition, valve and venting faults traced with a meter and a look up the vent, then only the failed part replaced.
DetailsFireplace Remodel
A new surround, mantel or fuel planned around the flue first, so the finished fireplace still vents well and clears its trim.
DetailsFireplace Inserts
An insert sealed into the firebox with its own stainless liner, sized to the unit's outlet and run to the top of the flue.
DetailsPellet Stove Repair
Feed, igniter, blowers and sensors tested, and the pressurized vent pipe checked joint by joint for leaks into the room.
DetailsWood Stove Repair
Door seals, baffle, firebrick and the stovepipe or liner renewed so the stove burns slowly and its exhaust stays sealed.
DetailsGas Logs
Log sets matched to the firebox floor and to the flue they vent through, with the gas line and valve fitted to code.
DetailsChimney Seismic Retrofit
Older brick stacks braced or reinforced at the roof, with the liner filmed first so the retrofit protects a working flue.
DetailsChimney Crown Repair
The concrete slab around the flue tile sealed or recast, so water stops running into the gap between tile and brick.
DetailsDryer Vent Cleaning
Lint cleared from the dryer duct all the way from the machine to the outside hood, with airflow measured before and after.
DetailsChimney Liner Installation
Stainless liners sized to the appliance and run in one piece from the firebox or insert up to the top of the flue.
DetailsChimney Leak Repair
Water traced from the stain indoors to where it enters, whether crown, flashing, brick or an open flue, then sealed there.
DetailsChimney Waterproofing
A breathable repellent applied to sound brick above the roof, so rain beads off without sealing moisture inside.
DetailsChimney Damper Repair
Throat dampers freed, refitted or replaced, or swapped for a sealing top damper mounted on the flue tile.