A stylish woman sitting in a vintage lounge area with subtle lighting and wooden decor.

Fireplace Remodel in Compton

Ask About Fireplace Remodel

Flue Filmed Joint by Joint
Liner Sized to the Appliance
Written Price Per Item
Footage Handed Over
Based in Compton
Flue Filmed Joint by Joint
Liner Sized to the Appliance
Written Price Per Item
Footage Handed Over
Based in Compton

The Work, Item by Item

A remodel often changes what burns in the fireplace, and that changes what the flue has to do. Before any tile or stone is chosen, we inspect the firebox and liner and tell you whether the existing flue suits the plan, needs a liner, or should give way to a direct-vent unit. Then we build the new face in tile, stone or plaster, fix the mantel to blocking and measure trim clearances. Remodels are priced once the design is settled.

Flue and firebox checked before design starts
Liner needs flagged for any fuel change
Tile, stone or plaster surrounds
Mantel fixed to solid blocking
Clearance to wood trim measured
Direct-vent unit offered where the flue cannot serve

Check the Chimney Before Picking Tile

Most remodel plans start with what you will see: new stone, a cleaner surround, a mantel in a different wood, maybe a gas unit in place of the open fire. The chimney behind it is easy to forget until something goes wrong. If the plan keeps a wood fire, the flue has to be sound and properly sized to the new opening; a smaller or larger firebox changes how the flue draws. If the plan switches to gas or an insert, the existing tile may be too big for the new appliance, which leads to a cold, slow draft and condensation, and the fix is a stainless liner sized to the unit. So the first step on a remodel in Compton is a look up the flue, often a Level 2 camera run at $370, so the design does not wrap new stone around a chimney that has to be opened up next year.

The rest of the planning is clearance and structure. Combustible trim needs space from the opening that depends on how far it projects, and the hearth in front has to be deep enough and built on a noncombustible base. Heavy stone veneer on an old brick face needs a way to hold on. Raising or extending a hearth changes where the floor finishes meet it. We sort these out on paper before work begins so the finished room passes inspection and you are not cutting new stone back to fit. The plan also covers the hidden parts that make a remodel last: a cleaned and checked smoke chamber, a sealed joint at the first flue tile, and, for gas, a shut-off valve placed where you can reach it once the new face is finished. Those are easy to do with the face open and hard to do afterward.

Common Remodels and How They Are Priced

The remodels we do most often around Compton, Downey and Cerritos are a new surround and hearth over an existing masonry fireplace, a dated 1970s or 1980s brick face covered in tile or stone, an open wood fireplace converted to gas with an insert, and a factory-built unit replaced with a new one. A gas unit fitted into the fireplace you already have runs $2,650 to $5,250 installed, including the liner it needs. A direct-vent gas unit framed into a wall where there was no fireplace before runs $4,200 to $8,400. Surrounds, hearths and mantels are priced in writing after we measure, because the materials and the size of the face vary too much to set a range. Every one of those starts with the same flue check, and the gas options include the liner they need in the price.

Your quote lists the flue work first, then the firebox, then the finish work, with a drawing of the layout and the clearances marked. If the flue needs a repair or liner, that line is separate so you can see what the chimney needs regardless of the look you choose. We do not ask you to commit to stone before the chimney has been checked. Before the old face comes off, we photograph it and the firebox so you have a record of what was there. Once the surround is open we sometimes find old patches, missing wall ties or charred framing near the opening; when we do, you see it before we close it up, and any extra line comes to you in writing first. The finished fireplace gets a final check of the clearances and, for gas, a leak test and a test fire. Use the form to describe what you have now and what you want the fireplace to be.

How Pemberton Chimney Contractors Works

Camera Before Price

The inside of the flue is seen before any figure is written

Sized Liners

Liner diameter worked out from the appliance outlet

Itemized Scope

Each repair on its own line with its own price

Footage Handed Over

Recordings and stills stay with you after the visit

Related Work

Chimney Sweep

A clean flue is a readable flue: brushes strip the deposits, then the camera checks each tile joint on the bare walls.

Details

Chimney Inspection

Flue tiles, liner joints and clearances read by eye and by camera, at whichever NFPA 211 level the chimney calls for.

Details

Chimney Repair

Repairs scoped from what the flue and brick show, ordered so the work that keeps heat and water in check comes first.

Details

Fireplace Inspection

Room side checked from firebox to smoke chamber, the narrowing where a fireplace meets its flue and heat damage often hides.

Details

Fireplace Repair

Firebrick, joints, smoke chamber parging and damper parts restored so the fire and its exhaust stay where they belong.

Details

Chimney Level 2 Inspection

Every foot of the flue filmed and saved, with the hidden stretches of chimney in the attic and crawl space checked too.

Details

Chimney Cap Installation

Stainless caps matched to the flue tile size and set high enough that rain and animals stay out while draft keeps moving.

Details

Chimney Flashing Repair

The metal seal where roof meets chimney rebuilt in overlapping layers, so roof runoff cannot slip behind the brick.

Details

Chimney Masonry Repair

Joints repointed, flaking brick replaced and the top courses checked, so rain stops reaching the flue tile from outside.

Details

Chimney Rebuilds

A failed stack taken down and laid up again around a new flue liner, sized for whatever will burn below it next.

Details

Fireplace Cleaning

Firebox, glass, hearth and surround cleaned on the room side, plus a light shone past the damper into the smoke chamber.

Details

Gas Fireplace Cleaning

Burner, pilot, logs and glass serviced, and the vent pipe checked so the exhaust from a gas flame leaves the house cleanly.

Details

Gas Fireplace Repair

Pilot, ignition, valve and venting faults traced with a meter and a look up the vent, then only the failed part replaced.

Details

Fireplace Inserts

An insert sealed into the firebox with its own stainless liner, sized to the unit's outlet and run to the top of the flue.

Details

Pellet Stove Repair

Feed, igniter, blowers and sensors tested, and the pressurized vent pipe checked joint by joint for leaks into the room.

Details

Wood Stove Repair

Door seals, baffle, firebrick and the stovepipe or liner renewed so the stove burns slowly and its exhaust stays sealed.

Details

Gas Logs

Log sets matched to the firebox floor and to the flue they vent through, with the gas line and valve fitted to code.

Details

Chimney Seismic Retrofit

Older brick stacks braced or reinforced at the roof, with the liner filmed first so the retrofit protects a working flue.

Details

Chimney Crown Repair

The concrete slab around the flue tile sealed or recast, so water stops running into the gap between tile and brick.

Details

Dryer Vent Cleaning

Lint cleared from the dryer duct all the way from the machine to the outside hood, with airflow measured before and after.

Details

Chimney Liner Installation

Stainless liners sized to the appliance and run in one piece from the firebox or insert up to the top of the flue.

Details

Chimney Leak Repair

Water traced from the stain indoors to where it enters, whether crown, flashing, brick or an open flue, then sealed there.

Details

Chimney Waterproofing

A breathable repellent applied to sound brick above the roof, so rain beads off without sealing moisture inside.

Details

Chimney Damper Repair

Throat dampers freed, refitted or replaced, or swapped for a sealing top damper mounted on the flue tile.

Details

Chimney Chase Cover

Rusted tops on framed chimneys replaced with stainless or aluminum covers made to measure around the metal flue.

Details